PT275 Force Speed Curve |
 |
About Force Speed Curve
- F=MA for the linear PackTrak system
- Speed Torque curve measured at 240 V, 3 phase
- For 220 V/208 V, proportionally reduce the plot
- Curve measured at maximum 20 Deg. C. ambient.
- Contact factory for higher temperatures up to a maximum of 45 Deg. C.
|
|
Specifications- PackTrak PT275
Motor Specifications– Our product line includes both straight and curved sections that may be joined to form an open or closed path, such as a racetrack. They are sealed and completely independent. Each section includes an absolute position encoder, multiple microprocessors and drive electronics.
| |
Item |
PT275 |
Units |
| Size (L x W x H) |
S500 Straight Section |
500 x 192.8 x 253.3 |
mm |
| Size (R x W x H) |
A180 Curved Section |
239 x 192.8 x 253.3 |
mm |
| Weight |
S500 Straight Section |
66 |
kg |
| |
A180 Curved Section |
68 |
kg |
| Environment |
Operating Temperature |
0 to 45 |
°C |
| |
Storage Temperature |
-10 to 70 |
°C |
| |
Washdown Rating |
IP65 |
|
| |
Humidity |
0 to 80 |
% |
| Position Encoder |
Type |
Absolute |
|
| |
Static Accuracy |
+/- 30 |
µm |
Movers– PackTrak movers are completely passive. They execute unique motions or follow a master profile.
| |
Item |
M75 |
Units |
| Size (L x W x H) |
Mover |
107 x 70 x 332 |
mm |
| Weight |
Mover |
2.7 |
kg |
| Environment |
Operating Temperature |
0 to 45 |
°C |
| |
Storage Temperature |
-10 to 70 |
°C |
| |
Rating |
IP65 |
|
| |
Humidity |
0 to 90 |
% |
| Speed |
Max. No Load Speed |
5 |
m/sec |
| Force |
Peak Force (standard force section) |
150 (33.7) |
N (lbf) |
| |
Peak Force (high force section) |
225 (50.6) |
N (lbf) |
|
|
|